The clinical relevance of serum c-glutamyltransferase (GGT) activity, in areas other than hepatic function, has recently been increased by several epidemiological associations. Still, GGT remains a nonspecific test because of the influence of various pathophysiological factors. We devised a procedure based on gel filtration chromatography, followed by postcolumn injection of fluorescent GGT substrate (cglutamyl- 7-amido-4-methylcoumarin), permitting the quantification of GGT fractions in serum or plasma. Plasma GGT molecular weight distribution was analyzed in healthy volunteers (20 males; mean ± SD age 38 ± 10 years; 20 females; age 44 ± 13; total GGT 21 ± 11 for males vs 13 ± 7 for females; P < 0.01). The method is highly sensitive (determination limit: 0.5 U GGT/L), with a linear dynamic range between 0.5 and 150 U/L for each fraction. Four GGT fractions of different molecular weight were detected in all subjects of both genders: b-GGT, m-GGT, s-GGT (likely lipoprotein-bound, molecular masses >2000, 940, and 140 kDa, respectively), and a free fraction (f-GGT, 70 kDa). f-GGT and s-GGT were the main fractions in subjects with lower and higher total GGT activity, respectively. Higher total GGT activity in males is related mainly to f-GGT (P < 0.01). GGT fraction analysis may increase the sensitivity and specificity of the GGT activity test.

A High Performance Gel Filtration Chromatography Method for gamma-Glutamyltransferase Fraction Analysis

FRANZINI, Maria;
2008-01-01

Abstract

The clinical relevance of serum c-glutamyltransferase (GGT) activity, in areas other than hepatic function, has recently been increased by several epidemiological associations. Still, GGT remains a nonspecific test because of the influence of various pathophysiological factors. We devised a procedure based on gel filtration chromatography, followed by postcolumn injection of fluorescent GGT substrate (cglutamyl- 7-amido-4-methylcoumarin), permitting the quantification of GGT fractions in serum or plasma. Plasma GGT molecular weight distribution was analyzed in healthy volunteers (20 males; mean ± SD age 38 ± 10 years; 20 females; age 44 ± 13; total GGT 21 ± 11 for males vs 13 ± 7 for females; P < 0.01). The method is highly sensitive (determination limit: 0.5 U GGT/L), with a linear dynamic range between 0.5 and 150 U/L for each fraction. Four GGT fractions of different molecular weight were detected in all subjects of both genders: b-GGT, m-GGT, s-GGT (likely lipoprotein-bound, molecular masses >2000, 940, and 140 kDa, respectively), and a free fraction (f-GGT, 70 kDa). f-GGT and s-GGT were the main fractions in subjects with lower and higher total GGT activity, respectively. Higher total GGT activity in males is related mainly to f-GGT (P < 0.01). GGT fraction analysis may increase the sensitivity and specificity of the GGT activity test.
2008
File in questo prodotto:
File Dimensione Formato  
2008a GGT fraction analysis.pdf

accesso aperto

Tipologia: Altro materiale
Licenza: PUBBLICO - Pubblico con Copyright
Dimensione 438.17 kB
Formato Adobe PDF
438.17 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/3163
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 57
social impact