Continuous and reliable cardiac function monitoring could improve medication adherence in patients at risk of heart failure. This work presents an innovative implantable Fiber Bragg Grating-based soft sensor designed to sense mechanical cardiac activity. The sensor was tested in an isolated beating ovine heart platform, with 3 different hearts operated in wide-ranging conditions. In order to investigate the sensor capability to track the ventricular beats in real-time, two causal algorithms were proposed for detecting the beats from sensor data and to discriminate artifacts. The first based on dynamic thresholds while the second is a hybrid convolutional and recurrent Neural Network. An error of 2.7 ± 0.7 beats per minute was achieved in tracking the heart rate. Finally, we have confirmed the sensor reliability in monitoring the heart activity of healthy adult minipig with an error systematically lower than 1 Bpm.

Implantable Fiber Bragg Grating sensor for continuous heart activity monitoring: ex-vivo and in-vivo validation

Davide Ferraro;Giacomo D’Alesio;Domenico Camboni;Ciro Zinno;Andrea Aliperta;Fabio Bernini;Valentina Casieri;Guido Giudetti;Jacopo Carpaneto;Silvestro Micera;Vincenzo Lionetti;Luca Massari;Calogero Maria Oddo
Supervision
2021-01-01

Abstract

Continuous and reliable cardiac function monitoring could improve medication adherence in patients at risk of heart failure. This work presents an innovative implantable Fiber Bragg Grating-based soft sensor designed to sense mechanical cardiac activity. The sensor was tested in an isolated beating ovine heart platform, with 3 different hearts operated in wide-ranging conditions. In order to investigate the sensor capability to track the ventricular beats in real-time, two causal algorithms were proposed for detecting the beats from sensor data and to discriminate artifacts. The first based on dynamic thresholds while the second is a hybrid convolutional and recurrent Neural Network. An error of 2.7 ± 0.7 beats per minute was achieved in tracking the heart rate. Finally, we have confirmed the sensor reliability in monitoring the heart activity of healthy adult minipig with an error systematically lower than 1 Bpm.
2021
File in questo prodotto:
File Dimensione Formato  
Ferraro_IEEE-Sensors_2021.pdf

solo utenti autorizzati

Tipologia: Documento in Post-print/Accepted manuscript
Licenza: Non pubblico
Dimensione 3.2 MB
Formato Adobe PDF
3.2 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/536503
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 13
social impact