Bladder cancer and urinary dysfunctions represent significant challenges to human health and patients' quality of life. Radical cystectomy is the primary treatment for muscle-invasive bladder cancer, but the associated bladder reconstruction surgery is unable to replicate the voiding capabilities of the native organ. In this scenario, the development of an implantable artificial bladder with controlled voiding capabilities has the potential to overcome the limitations of current clinical solutions. This study explores the synergy between an artificial bladder and an active artificial detrusor constituted by two soft actuators integrated on a soft sleeve. In particular, hydraulic balloon actuators have been selected to enhance the voiding performances of the artificial bladder while preserving softness for smooth and minimally-invasive implantation. Experimental results demonstrate that the actuators can reach a displacement of 31.0 ± 0.7 mm at 40 mL inlet volume and generate output forces of 26.4 ± 3.4 N, 6.8 ± 1.4 N, and 1.5 ± 0.4 N at 25%, 50%, and 75% of the maximum displacement, respectively. The soft detrusor enables promising voiding capabilities of the artificial bladder in terms of Post-Voiding Residual (PVR) volume, Voiding Efficiency (VE), and Voiding Time (VT), reaching values equal to 2.2 ± 2.0 mL, 98.9 ± 1.0 %, and 83.9 ± 4.7 s, respectively.

A Soft Robotic Detrusor Based on Balloon Hydraulic Actuators for Artificial Bladder Voiding

Galassi, Laura;Paterno, Linda;Semproni, Federica;Onorati, Simone;Iacovacci, Veronica;Menciassi, Arianna
2024-01-01

Abstract

Bladder cancer and urinary dysfunctions represent significant challenges to human health and patients' quality of life. Radical cystectomy is the primary treatment for muscle-invasive bladder cancer, but the associated bladder reconstruction surgery is unable to replicate the voiding capabilities of the native organ. In this scenario, the development of an implantable artificial bladder with controlled voiding capabilities has the potential to overcome the limitations of current clinical solutions. This study explores the synergy between an artificial bladder and an active artificial detrusor constituted by two soft actuators integrated on a soft sleeve. In particular, hydraulic balloon actuators have been selected to enhance the voiding performances of the artificial bladder while preserving softness for smooth and minimally-invasive implantation. Experimental results demonstrate that the actuators can reach a displacement of 31.0 ± 0.7 mm at 40 mL inlet volume and generate output forces of 26.4 ± 3.4 N, 6.8 ± 1.4 N, and 1.5 ± 0.4 N at 25%, 50%, and 75% of the maximum displacement, respectively. The soft detrusor enables promising voiding capabilities of the artificial bladder in terms of Post-Voiding Residual (PVR) volume, Voiding Efficiency (VE), and Voiding Time (VT), reaching values equal to 2.2 ± 2.0 mL, 98.9 ± 1.0 %, and 83.9 ± 4.7 s, respectively.
File in questo prodotto:
File Dimensione Formato  
A_Soft_Robotic_Detrusor_Based_on_Balloon_Hydraulic_Actuators_for_Artificial_Bladder_Voiding.pdf

non disponibili

Tipologia: PDF Editoriale
Licenza: Copyright dell'editore
Dimensione 631.62 kB
Formato Adobe PDF
631.62 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/582639
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
social impact