Accurate gait phase estimation algorithms can be used to synchronize the action of wearable robots to the volitional user movements in real time. Current-day gait phase estimation methods are designed mostly for rhythmic tasks and evaluated in highly controlled walking environments (namely, steady-state walking). Here, we implemented adaptive Dynamic Movement Primitives (aDMP) for continuous real-time phase estimation in the most common locomotion activities of daily living, which are level-ground walking, stair negotiation, and ramp negotiation. The proposed method uses the thigh roll angle and foot-contact information and was tested in real time with five subjects. The estimated phase resulted in an average root-mean-square error of 3.98% ± 1.33% and a final estimation error of 0.60% ± 0.55% with respect to the linear phase. The results of this study constitute a viable groundwork for future phase-based control strategies for lower-limb wearable robots, such as robotic prostheses or exoskeletons.

Continuous Phase Estimation in a Variety of Locomotion Modes Using Adaptive Dynamic Movement Primitives

Eken, Huseyin
;
Pergolini, Andrea;Mazzarini, Alessandro;Livolsi, Chiara;Fagioli, Ilaria;Penna, Michele Francesco;Trigili, Emilio;Crea, Simona;Vitiello, Nicola
2023-01-01

Abstract

Accurate gait phase estimation algorithms can be used to synchronize the action of wearable robots to the volitional user movements in real time. Current-day gait phase estimation methods are designed mostly for rhythmic tasks and evaluated in highly controlled walking environments (namely, steady-state walking). Here, we implemented adaptive Dynamic Movement Primitives (aDMP) for continuous real-time phase estimation in the most common locomotion activities of daily living, which are level-ground walking, stair negotiation, and ramp negotiation. The proposed method uses the thigh roll angle and foot-contact information and was tested in real time with five subjects. The estimated phase resulted in an average root-mean-square error of 3.98% ± 1.33% and a final estimation error of 0.60% ± 0.55% with respect to the linear phase. The results of this study constitute a viable groundwork for future phase-based control strategies for lower-limb wearable robots, such as robotic prostheses or exoskeletons.
File in questo prodotto:
File Dimensione Formato  
ICORR23_Eken_ICORR_2023_v8_CleanVersion.pdf

non disponibili

Tipologia: Documento in Post-print/Accepted manuscript
Licenza: Creative commons (selezionare)
Dimensione 686.91 kB
Formato Adobe PDF
686.91 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11382/572955
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
social impact