Accurate gait phase estimation algorithms can be used to synchronize the action of wearable robots to the volitional user movements in real time. Current-day gait phase estimation methods are designed mostly for rhythmic tasks and evaluated in highly controlled walking environments (namely, steady-state walking). Here, we implemented adaptive Dynamic Movement Primitives (aDMP) for continuous real-time phase estimation in the most common locomotion activities of daily living, which are level-ground walking, stair negotiation, and ramp negotiation. The proposed method uses the thigh roll angle and foot-contact information and was tested in real time with five subjects. The estimated phase resulted in an average root-mean-square error of 3.98% ± 1.33% and a final estimation error of 0.60% ± 0.55% with respect to the linear phase. The results of this study constitute a viable groundwork for future phase-based control strategies for lower-limb wearable robots, such as robotic prostheses or exoskeletons.
Continuous Phase Estimation in a Variety of Locomotion Modes Using Adaptive Dynamic Movement Primitives
Eken, Huseyin
;Pergolini, Andrea;Mazzarini, Alessandro;Livolsi, Chiara;Fagioli, Ilaria;Penna, Michele Francesco;Trigili, Emilio;Crea, Simona;Vitiello, Nicola
2023-01-01
Abstract
Accurate gait phase estimation algorithms can be used to synchronize the action of wearable robots to the volitional user movements in real time. Current-day gait phase estimation methods are designed mostly for rhythmic tasks and evaluated in highly controlled walking environments (namely, steady-state walking). Here, we implemented adaptive Dynamic Movement Primitives (aDMP) for continuous real-time phase estimation in the most common locomotion activities of daily living, which are level-ground walking, stair negotiation, and ramp negotiation. The proposed method uses the thigh roll angle and foot-contact information and was tested in real time with five subjects. The estimated phase resulted in an average root-mean-square error of 3.98% ± 1.33% and a final estimation error of 0.60% ± 0.55% with respect to the linear phase. The results of this study constitute a viable groundwork for future phase-based control strategies for lower-limb wearable robots, such as robotic prostheses or exoskeletons.File | Dimensione | Formato | |
---|---|---|---|
ICORR23_Eken_ICORR_2023_v8_CleanVersion.pdf
non disponibili
Tipologia:
Documento in Post-print/Accepted manuscript
Licenza:
Creative commons (selezionare)
Dimensione
686.91 kB
Formato
Adobe PDF
|
686.91 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.